PHMETROS MAYRON PARA LAS ARTES GRAFICAS

AG6/PH FEATURES
-
Checks soil pH and salinity
-
Checks water pH and salinity
-
Checks correct fertilizer concentration
-
Checks boiler water conductivity
-
Automatic temperature compensation means no thermometers or adjustments
-
Only small amount of soil needed for tests
AG-5 FEATURES
Plant health can be greatly affected by pH (acidic or basic), salinity (soluble salts), and alkalinity, yet these factors are often ignored by growers. It is easy to test for these three important parameters using a portable MyronL AGRI-METER with Soil Test Kit.
SOILS
Optimum soil pH is essential for obtaining maximum efficiency from fertilizers and herbicides.
|
This is especially true for artificial growing media which, without buffering capability, are much more pH sensitive than natural soil. In addition, the pH of artificial soils can vary greatly when new, and must be adjusted (leached) before use.
Dissolved salts (salinity) in soil must also be monitored to guarantee healthy plants. Salt build-up in soil can be due to high TDS (total dissolved solids) in water, excess fertilizer, or poor drainage. Each plant has its own salinity tolerance level. If excessive salts accumulate in the soil, roots will take in little or no soil solution, resulting in reduced plant growth and quality.
Using a Myron L Model AG6/PH for checking soil salinity and pH is easy. Simply mix one part soil with two parts pure water in the vials provided with the Soil Test Kit. Some organic media, such as peat moss, need a 5:1 water: soil dilution ratio. Only a heaping tablespoon of soil is required. Agitate container vigorously. Let settle for 45-60 minutes and decant the water into the instrument cell cup. Push buttons to read directly in millimhos/conductivity (salinity) and soil pH.
|
FERTILIZER SOLUTIONS
Regular testing of conductivity insures that fertilizer solutions will contain the optimum level of salinity for maximum plant health and growth. If a fertilizer injection system is used, it can be easily checked with an AGRI-METER by taking a sample solution as it comes out of the end of the hose or “spaghetti” irrigation tubes. Proper adjustment of the fertilizer injector can prevent these common problems: over or under feeding, plant damage and fertilizer waste.
WATER
Water pH can vary greatly from month to month because of rainfall effect on the aquifer. Irrigation water, if high in soluble salts, can increase soil salinity causing plant damage. AGRI-METER tests water pH and salinity easily and quickly, and readings are given directly in millimhos/conductivity.
The correct pH of water used in pesticide solutions is also important in order to insure maximum effectiveness and prevent pesticide “break down”.
|
The correct pH of water used in pesticide solutions is also important in order to insure maximum effectiveness and prevent pesticide “break down”.
ALKALINITY tests are critical to proper pH adjustments of water and floral preservative solutions. The Soil Test Kit includes a simple and quick ppm alkalinity test.
|

|
SIMPLE TO OPERATE
Step 1: Rinse AGRI-METER built-in cell cup and fill with sample.
Step 2: Push black button and read conductivity.
Step 3: Push red button of Model AG6/PH and read pH
|
|
CONDUCTIVITY TERMINOLOGY
Both AG-5 and AG6/PH AGRI-METERS are calibrated in millimhos, the term most widely used by growers to express electrical conductivity. Some charts may read in other units called micromhos. However, since one millimho equals 1,000 micromhos, conversion is easy. Parts per million (ppm) is also sometimes used. Conductivity/ppm fertilizer concentration tables can be obtained from your supplier, consultant, or university advisor.
Accessories
Soil Test Kit: Sturdy, foam-lined polyethylene carrying case, soil mixing vials, calibration solutions and ppm/alkalinity test; Model STK for AG-5, Model PSTK for AG6/PH.
Conductivity Standard Solution: Every AGRI-METER is factory calibrated with a Standard Solution of known Conductivity value (3.9 millimhos/3900 micromhos). Your instrument will be kept most accurate by periodic recalibration with the same type 442-3000 Standard Solution.
pH Buffer Solutions: Available in 4, 7, and 10 pH values; they assure an accuracy of ±0.2 pH units on every test. pH 7 Buffer is especially important, and should be used every two weeks. All Myron L pH buffers are traceable to N.I.S.T. certified pH references, and color coded for instant identification.
Replacement pH Sensor: Model RPY is a unique non-refillable KCI gel-filled pH combination electrode, featuring a porous liquid junction. Complete installation instructions included.
|
CONDUCTIVIMETROS MAYRON PARA ARTES GRAFICAS
Advanced Design ● Superior Performance

|
Since 1957, the Myron L Company has designed and manufactured highly reliable analytical instruments for a wide variety of applications. Thousands of professionals around the world rely every day on the performance of our instruments. Demanding uses range from boiler water testing to ultrapure water control to medical instruments for artificial kidney machines.
We are proud of the trust our handheld instruments and monitor/controllers have earned in the past. Our product line has evolved to a new level of outstanding performance and value in analytical instruments: the Ultrameter II series. While priced like affordable single-parameter instruments, the Ultrameter II does the job of three, four or even six instruments. See data sheet for additional information
|
Accuracy You Can Trust
Both Ultrameter II models deliver performance of ±1% of reading (not merely full scale). This high level of accuracy has been achieved through advanced four-electrode conductivity cell technology, a unique pH/ORP sensor and powerful microprocessor based circuitry. With displayed values of up to 9999, the full four-digit LCD ensures resolution levels never before possible in such affordable instruments. Factory calibrated with NIST traceable solutions, each Ultrameter II may be supplied with both certification of traceability and NIST traceable solutions for definitive calibration.
Fast and accurate
in the laboratory, both
Ultrameter II models
are rugged enough for
daily in-line controller
checks in hostile
process applications.
Innovative Engineering
The Ultrameter II is a prime example of how high-tech engineering can greatly simplify and streamline a task. Whether in the lab, industrial plant, or in a remote field location, merely:
-
Fill the cell cup
-
Push a parameter key
-
Take the reading
Temperature compensation and range selection are both rapid and automatic. The Ultrameter II is a true one-hand operation instrument.
Easy to Calibrate
All calibrations are quickly accomplished by pressing the ▲ or ▼ keys to agree with our NIST traceable Standard Solution. When calibration is necessary, display prompts simplify pH calibration and make sure the correct buffer is being used. Plus, all parameters (excluding factory-set temperature) have an internal electronic setting that can be used for field calibration and as a check on pH/ORP sensor life.
Advanced Features
-
Fully automatic temperature compensation
-
User adjustable temperature compensation (up to 9.99%/°C) which also allows TC to be disabled for applications requiring non-compensated readings.
-
User adjustable conductivity/TDS conversion ratio for greater accuracy when measuring solutions not contained in the microprocessor.
-
Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests.
-
Non-volatile microprocessor provides data back-up, even when the battery is changed. This assures all calibrations and memory data will be retained.
-
Extended life pH/ORP sensor is user replaceable in the field.
High Performance at a Low Cost
Beyond their affordable purchase price, Ultra-Fast, Ultra-Easy, Ultra- Powerful Ultrameter II‘s save both time and money. Measure for measure, Ultrameter II‘s give you a better return on your investment than any other handheld instrument. To see for yourself, contact your distributor or the Myron L Company today.
Multiple Applications
Irrigation Water
Hydroponics
Laboratories
Homeland Security
Reverse Osmosis
Deionization
Wastewater
Cooling Towers
Environmental
Desalination
Fountain Solutions
|

Built-in IR Port allows you to conveniently download your data to a computer. (Requires Myron L uDock™ Accessory Package)
Ample memory provides increased flexibility to record and store 100 separate readings.
Real Time Clock with Date & Time Stamp allows you to maintain the integrity of each individual reading.

The advanced four-electrode cell for conductivity/ resistivity/TDS eliminates polarization, allowing greater accuracy and stability with minimal maintenance.
The pH/ORP sensor chamber provides protection to a unique porous liquid-junction.
The large capacity KCI reservoir guarantees extended life.

A custom LCD helps simplify calibration and operation by using annunciators and prompts to indicate various conditions

IP67/NEMA 6 rated Ultrameter II‘s are waterproof and buoyant and can be fully immersed to 3 feet/1 meter.
|
Accessories
uDock™ Accessory Package includes uDock™, USB cable and Macintosh/PC application software for downloading data.
model: U2CIP
Certificates confirming the NIST traceability of an Ultrameter II are available (must be specified when placing instrument order).
model: MC
Conductivity Standard Solutions are necessary to maintain accuracy and for periodic calibration of conductivity/TDS parameters. All Standard Solutions are NIST traceable for your complete confidence. recommended values: KCl- 7000 (7 mS), 442-3000 (TDS), or NaCl-14.0 (mS) available in 2 oz/59 ml, 1 qt/1 L, and
1 gal/3,8 L.
|
pH Buffers are necessary to maintain accuracy and for periodic calibration of pH and ORP parameters. Calibration with pH 7 Buffer is especially important. All pH 4, 7, and 10 Buffers are NIST traceable and are available in 2 oz/59 ml, 1 qt/1 L, and 1 gal/3,8 L.
pH Sensor Storage Solution Available in 2 oz/59 ml, 1 qt/1 L, and 1 gal/3,8 L. model: SS20Z, SSQ and SSG
Certificate of NIST traceability for pH Buffer or Conductivity Standard Solutions are available (must be specified when placing solution order). model: SC
Hard protective case (small)
model: UPP
|
|
MEDIDOR DE CONDUCTIVIDAD MAYRON EL MAS COMUN PARA ARTES GRAFICAS

description
This manual describes your Myron L DS Meter™, tells
you how to use it, and how to keep it working accurately
for many years.
Your model 532 three range DS Meter is a compact
instrument which operates on the principle of electrical
conductivity. It will quickly determine the conductivity or
ppm/Total Dissolved Solids of almost any solution. Model
532M1 has a dial calibrated in micromhos (μmhos), which
is equivalent to the metric microsiemens (μS). Models
532T1 and 532T2 convert the conductivity directly into
parts per million (ppm) of Total Dissolved Solids. All are
3.4” x 4.5” x 4.0” (85 x 129 x 126mm) and weigh less than
one pound (.45 kg). DS Meters are completely selfcontained.
The built-in cell is automatically temperature
compensated from 50º to 160ºF (10º to 71ºC). They are
powered by a 9 volt battery good for at least 2000 tests, or
one year shelf life.
model ranges
532T1 0-50, 0-500, 0-5000 ppm
532T2 0-25, 0-250, 0-2500 ppm
532M1 0-50, 0-500, 0-5000 μmho
By using an RE-10 Range Extender (see
accessories), the maximum range of each meter may
be increased ten times.