
|
VISCOSIMETROS ANALOGOS Y DIGITALES(Tambien usados)
Instrumentos de medición y control de viscosidad, indispensables en el control de calidad de innumerables productos. todos se suministran con certificado de fábrica, juego de agujas, instructivo, estuche y soporte. Todos los viscosímetros Brookfield utilizan el conocido principio de la viscosimetria rotacional; miden la viscosidad captando el par de torsión necesario para hacer girar a velocidad constante un husillo inmerso en la muestra de fluido. El par de torsión es proporcional a la resistencia viscosa sobre el eje sumergido, y en consecuencia, a la viscosidad del fluido.
Son de fácil manejo e instalación, sin necesidad de un alto grado de conocimientos operativos.
De gran versatilidad, cuentan con una amplia gama de viscosidades
___________________________
Dial Reading Viscometer |
Now it's improved with a multi-speed electronic drive and ergonomically designed speed control knob.
Quickly select any one of 10 pre-set speeds (8 speeds on LVT models).
- Continuous torque sensing capability
- Torque measurement accuracy: 1% of full scale range; Repeatability: 0.2% of full scale range
- Easy speed adjustment and on/off control
- Compatible with all Brookfield accessories
- NIST traceable viscosity standards available
- Electronic drive means quiet, reliable operation
- Universal power supply worldwide compatibility
- 2-Year limited warranty
Brochure (PDF) Selection Chart Manual (PDF)
Manual (older models) (PDF)
.
|
|

LVT Dial Reading
(Analogue)
Click to enlarge |
DV-E Viscometer |
The digital display ensures easy and accurate readout of test results for simultaneous measurement of viscosity and torque.
The DV-E combines economy and ease of operation with traditional Brookfield excellence.
- Low cost and easy to use
- Direct display in:
- cP or mPa·s
- % Torque, Spindle, and Speed
- Torque measurement accuracy: 1% of full scale range; Repeatability: 0.2% of full scale range
- Compatible with all Brookfield accessories
- NIST traceable viscosity standards available
- 18 speeds for greater range capability (0.3 to 100 rpm)
Brochure(PDF) Selection Chart Manual (PDF)
.
|
|

DV-E
Click to enlarge |
DV-I Prime Viscometer |
Continuous sensing capability for rapid viscosity measurement.
DV-I Prime measures viscosity and temperature simultaneously (with an optional temperature probe). With its timed measurement function, data can easily be sent to a PC or printer. Optional software allows the DV-I Prime to collect, analyze and record test data.
- PC Interface for use with optional Wingather Software and output connection to printer
- Direct access to time measurement function (time to torque, time to stop)
- Temperature off-set capability to ±5°C
- Senses and displays continuously:
- Viscosity (cP or mPa·s)
- Temperature (°C or °F) (OPTIONAL)
- % Torque
- Speed (rpm)
- Spindle used
- Torque measurement accuracy: 1% of full scale range; Repeatability: 0.2% of full scale range
- Choice of 18 rotational speeds
- Optional RTD temperature probe
- Auto-range function to define full scale range (FSR) for all spindle/speed combinations
- Compatible with all Brookfield accessories
- NIST traceable viscosity standards available
Brochure (PDF) Selection Chart Manual (PDF)
.
|
|

DV-I Prime
Click to enlarge |
DV-II+ Pro Viscometer |
Continuous sensing, temperature measurement and data output to PC or printer.
When controlled by PC, the DV-II+ PRO becomes a Rheometer with variable speed capability from 0.01 to 200 rpm. This is one of the most popular instruments offered by Brookfield in this category.
- Continuous display of: Viscosity (cP or mPa·s), Temperature (°C or °F), Shear Rate, Shear Stress, % Torque, Spindle
- Torque measurement accuracy: 1% of full scale range; Repeatability: 0.2% of full scale range
- 54 selectable speeds provide superior range of viscosity/shear measurements for use in stand-alone operation
- Download custom programs with DV Loader software (included)
- Automate program control by PC running optional Rheocalc software; speed control from 0.01 to 200 rpm
- Automatic data collection and historical comparison with optional Wingather software
- Built-in RTD temperature probe
- Parallel printer, serial RS-232 and analog voltage outputs
- Compatible with all Brookfield accessories
- NIST traceable viscosity standards available
Brochure (PDF) Selection Chart Manual (PDF)
.
|
|

DV-II+PRO
Click to enlarge |
Wells-Brookfield Cone/Plate Viscometer |
This geometry gives researchers a sophisticated instrument for routinely determining absolute viscosity of fluids in small sample volumes.
The Wells-Brookfield Cone/Plate Viscometer/Rheometer provides a wide variety of shear rates and viscosity ranges, which can be further extended by the use of interchangeable cone spindles. Different models can be selected to meet the specific range of viscosities and shear rates required.
Shear rates as high as 1,875 sec-1 (DV-III Ultra Rheometer) can be achieved. The small sample volume required permits rheological evaluations to be made on materials where sample availability is limited, such as biological fluids and thick film coatings that contain precious metals. All wetted parts are stainless steel for corrosion resistance and ease of cleaning.
Optional purge fitting, luer fitting, and embedded temperature probe available.
Wells-Brookfield Cone/Plate Digital Viscometers/Rheometers are now supplied with an advanced Electronic Gap Setting feature. This technology allows faster set-up time and minimizes the possibility of gap adjustment errors.
- Determine absolute viscosity of small samples (0.5 - 2.0 mL)
- Precise shear rates for determining a material's flow curve behavior
- Rapid temperature control due to small sample size
- Electronic gap adjustment for simplified setup and increased throughput
- Available on DV-III Ultra Rheometer and DV-II+Pro and DV-I Prime Viscometers
- Automatic data collection and historical comparison with optional Wingather software (for DV-I Prime and DV-II+PRO models) and Rheocalc software (for DV-II+PRO and DV-III Ultra models)
- Torque measurement accuracy: 1% of full scale range; Repeatability: 0.2% of full scale range
- NIST traceable viscosity standards available
Brochure (PDF) Selection Chart
.
|
|

DV-III Ultra CP
Click to enlarge
v
Cone and Plate Setup
Click to enlarge

Cone Spindle
Click to enlarge |
High Shear CAP 1000+ and 2000+ Viscometers |
The CAP series Viscometers are compact, heavy-duty instruments that are ideal for fast, easy, repetitive testing on the production floor or in the QC lab. CAP-2000+ offers expanded temperature and viscosity ranges with variable speed capability.
CAP 1000+ Features:
- Quick single point test
- Choice of shear rate. Standard speeds include 750 and 900 rpm to provide shear rate at 10,000 sec-1
- Rapid temperature control with built-in Peltier element in sample plate
- Meets Industry Standards:
- Rugged Design Can Handle Production Environment
- Rugged design can handle production environment
- Small Sample Size, < 1 mL, Simplifies Testing
- Easy to Clean
- Parallel printer output
CAP 2000+ Features:
- Expanded Ranges
Viscosity |
0.2 - 15,000 Poise |
Shear Rate |
10 - 13,000 sec-1 |
Temperature |
5-75°C or 50-235°C |
Speed of Rotation |
5-1000 RPM |
- Meets Industry Standards:
- Small sample size, < 1 mL, simplifies testing
- Rapid temperature control with built-in Peltier element in sample plate
- Optional CAPCALC software for complete control and data analysis
- Open system for quick and easy cleaning
Brochure (PDF) CAP1000+ Chart CAP2000+ Chart
Manual CAP1000+ (PDF) Manual CAP2000+ (PDF)
|
|

CAP 1000+
Click to enlarge

CAP 20000+
Click to enlarge |
KU-2 (Krebs Units) Viscometer |
KU-2 is used widely for making viscosity measurements on paints/coatings in accordance with ASTM D562.
A digital calculating Krebs Unit Instrument, now with relative centipoises display.
- Continuous sensing and display in Krebs units, grams, and centipoise
- LED Digital Display of:
- Krebs Units (increased resolution in 0.1 KU increments)
- Grams (in 1 gm increments)
- Centipoise (cP)
- Expanded measurement range (40 to 141 KU; 32 to 1099 g; 27 to 5274 cP).
- Accuracy to ±1% of full scale range.
- Reproducibility to ±0.5% of full scale range.
- Output to parallel printer for automatic test documentation.
- Easy to use; no weights; simplifies an established test procedure.
- Compatible with industry specification (ASTM D562).
- Base accommodates standard pint, ½ pint, and quart cans.
- Optional air purge allows interior of KU-2 to be pressurized with air or inert gas.
- The optional paste spindle is suitable for use with high consistency materials such as roller mil pastes.
- NIST traceable viscosity standards available
Brochure (PDF) KU-1+ Manual (PDF)
|
NOTA DESCARGAS DE MANUALES
1.-LV,RV,HA,HB" DIAL" (CLICK)
2.- New Dial Viscometer - Electronic Drive( CLICK)
3.- Digital Viscometer model DV-E (English) LVDV-E, RVDV-E, HADV-E, HBDV-E
4.- Digital Viscometer model DV-I+ MOD: LVDV-I+, RVDV-I+, HADV-I+, HBDV-I+(CLICK)
5.- Digital Viscometer model DV-II+ Programmable MODEL:
|